Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 60

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Individual exposure dose assessment of residents for lifting of evacuation orders (Contract research)

Sato, Rina; Sanada, Yukihisa; Yoshimura, Kazuya; Nakayama, Mariko*

JAEA-Review 2022-055, 42 Pages, 2023/01

JAEA-Review-2022-055.pdf:1.31MB

The evacuation order zones established after the accident at the Tokyo Electric Power Company's Fukushima Daiichi Nuclear Power Station have been reorganized according to the decrease in ambient dose equivalent rates and the decontamination progress. It has been decided to decontaminate the difficult-to-return zones and lift the evacuation order depending on the evacuee's intention of returning to the areas over the course of the 2020s. In order to consider the future of individual exposure dose assessment for residents for lifting of the evacuation orders, the methods and characteristics of the assessment that have been conducted after the accident using personal dosimeter measurements and simulations were systematically reviewed. This report summarized the results of the review.

JAEA Reports

Result of measurement of the ambient dose equivalent rates by car-borne surveys using KURAMA-II from 2012 until 2019

Ando, Masaki; Saito, Kimiaki

JAEA-Technology 2021-032, 66 Pages, 2022/03

JAEA-Technology-2021-032.pdf:3.84MB

Since the occurrence of the accident at the TEPCO Fukushima Daiichi Nuclear Power Station, the Japan Atomic Energy Agency (JAEA) has been conducting a series of car-borne survey over a wide area in the eastern part of Japan using the monitoring system KURAMAII. In this report, outline of the car-borne surveys are summarized and the following characteristics of the temporal changes in each prefecture and region were investigated using the measured data obtained from 2012 to 2019; 1) Average and maximum values for each prefecture for the six years from 2014 to 2019, 2) Average values for each prefecture from 2012 to 2019, 3) Average values for each evacuation order area category, regional category, and northern Soso-area municipality in Fukushima Prefecture from 2012 to 2019, and 4) Average and maximum values for each municipality in each prefecture for four times (at almost two-year intervals) of the measurement results from 2012 to 2018.

Journal Articles

Determination of parameters for an equation to obtain natural background radiation using KURAMA-II loaded with C12137-01 type CsI(Tl) detector

Ando, Masaki; Matsuda, Norihiro; Saito, Kimiaki

Nihon Genshiryoku Gakkai Wabun Rombunshi, 20(1), p.34 - 39, 2021/03

We measured count rates and air dose rates at 11 measurement points where the influence of the Fukushima Dai-ichi Nuclear Power Plant accident could be ignored to obtain parameters for a background equation applying to KURAMA-II loaded with the high sensitivity CsI(Tl) detector, C12137-01. It was found that the sensitivity of KURAMA-II (C12137-01) was about 10 times or more for background measurement, compared with KURAMA-II loaded with the standard type CsI(Tl) detector, C12137. A background equation for the energy range of 1400-2000 keV was determined as, y ($$mu$$Sv/h)=0.062 x (cps). We evaluated background air dose rates using KURAMA-II (C12137-01) for 71 municipalities and compared them with the previous study using KURAMA-II (C12137). Evaluated background air dose rates in this study were almost equal to those in the previous study. We confirmed that the background equation evaluated in this study was applicable for the KURAMA-II (C12137-01).

Journal Articles

Calculations for ambient dose equivalent rates in nine forests in eastern Japan from $$^{134}$$Cs and $$^{137}$$Cs radioactivity measurements

Malins, A.; Imamura, Naohiro*; Niizato, Tadafumi; Takahashi, Junko*; Kim, M.; Sakuma, Kazuyuki; Shinomiya, Yoshiki*; Miura, Satoru*; Machida, Masahiko

Journal of Environmental Radioactivity, 226, p.106456_1 - 106456_12, 2021/01

 Times Cited Count:6 Percentile:35.21(Environmental Sciences)

Journal Articles

Initial decrease in the ambient dose equivalent rate after the Fukushima accident and its difference from Chernobyl

Yoshimura, Kazuya; Saegusa, Jun; Sanada, Yukihisa

Scientific Reports (Internet), 10(1), p.3859_1 - 3859_9, 2020/03

 Times Cited Count:16 Percentile:64.78(Multidisciplinary Sciences)

Journal Articles

Decreasing trend of ambient dose equivalent rates over a wide area in eastern Japan until 2016 evaluated by car-borne surveys using KURAMA systems

Ando, Masaki; Mikami, Satoshi; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Saito, Kimiaki

Journal of Environmental Radioactivity, 192, p.385 - 398, 2018/12

 Times Cited Count:14 Percentile:45.76(Environmental Sciences)

Car-borne surveys using KURAMA systems have been conducted over a wide area in eastern Japan since 2011. The measurement data collected until 2016 was analyzed, and decreasing trend of the dose rates in regions within 80 km of Fukushima Dai-ichi Nuclear Power Plant were examined. The averaged dose rates tended to decrease considerably with respect to the physical decay of radiocaesium, and the ecological half-lives of the fast and slow decay components were estimated. The decrease of the dose rate in the forest was slower than its decrease in other regions, and the decrease of the dose rate in urban area was the fastest. The decrease in the dose rates obtained via the car-borne survey was larger than that obtained on flat ground with few disturbances using survey meters approximately 1.5 y after the accident; hereafter, the decrease in the dose rates obtained via the car-borne survey was same as the latter measurement.

Journal Articles

Measurement of ambient dose equivalent rates by walk survey around Fukushima Dai-ichi Nuclear Power Plant using KURAMA-II until 2016

Ando, Masaki; Yamamoto, Hideaki*; Kanno, Takashi*; Saito, Kimiaki

Journal of Environmental Radioactivity, 190-191, p.111 - 121, 2018/10

 Times Cited Count:17 Percentile:52.92(Environmental Sciences)

Ambient dose equivalent rates in various environments related to human lives were measured by walk surveys using the KURAMA-II systems from 2013 to 2016 around the Fukushima Dai-ichi Nuclear Power Plant. The dose rate of the locations where the walk survey was performed decreased to about 38% of its initial value in the 42 months, which was beyond that attributable to the physical decay. The air dose rates decreased depending on the level of the evacuation areas, and the decrease was slightly larger in populated areas where humans are active. The comparison of walk survey data with car-borne survey data indicated that the air dose rate varies largely even within a 100 m square area. The dose rates measured by the walk surveys were estimated to be medial of those along roads and those of undisturbed flat ground. The air dose rates measured by the walk surveys decreased quickly compared with the air dose rate from the flat ground measurement.

Journal Articles

Calculation of fluence-to-effective dose conversion coefficients for the operational quantity proposed by ICRU RC26

Endo, Akira

Radiation Protection Dosimetry, 175(3), p.378 - 387, 2017/07

 Times Cited Count:11 Percentile:72.62(Environmental Sciences)

The International Commission on Radiation Units and Measurements (ICRU) has been discussing to propose a new system of the operational quantities for external radiations based on protection quantities. The aim of this study is to provide a set of conversion coefficients for use in defining personal dose equivalent for individual monitoring. Fluence-to-effective dose conversion coefficients have been calculated for photons, neutrons, electrons, positrons, protons, muons, pions and helium ions for various incident angles of radiations. The data sets comprise effective dose conversion coefficients for incident angles of radiations from 0 $$^{circ}$$ to 90 $$^{circ}$$ in steps of 15$$^{circ}$$ and at 180$$^{circ}$$. Conversion coefficients for rotational, isotropic, superior hemisphere semi-isotropic and inferior hemisphere semi-isotropic irradiations are also included. The conversion coefficients are used to define the operational quantity personal dose equivalent which is being considered by ICRU and utilized for the design and calibration of dosemeters.

Journal Articles

The Evaluation of the 0.07 mm and 3 mm dose equivalent with a portable beta spectrometer

Hoshi, Katsuya; Yoshida, Tadayoshi; Tsujimura, Norio; Okada, Kazuhiko

JPS Conference Proceedings (Internet), 11, p.070009_1 - 070009_6, 2016/11

Beta spectra of various nuclide species were measured by commercially available compact spectrometer. The shape of spectra obtained from the spectrometer approximately agreed with that of theoretical spectra. The beta dose equivalent at any depths has been able to be obtained as a product of measured pulse height spectra and appropriate conversion coefficients of ICRP Publ. 74. The dose rates evaluated from the spectra were comparable to the reference dose rates of standard beta calibration sources. And, we were able to determine the dose equivalent with relative error of indication of 10% without the complicated correction.

Journal Articles

Measurement of the stochastic radial dose distribution for a 30-MeV proton beam using a wall-less tissue-equivalent proportional counter

Tsuda, Shuichi; Sato, Tatsuhiko; Ogawa, Tatsuhiko

Radiation Protection Dosimetry, 168(2), p.190 - 196, 2016/02

 Times Cited Count:2 Percentile:19.71(Environmental Sciences)

Deposit energy distribution in microscopic site in a living cell is important information for understanding of biological effects of energetic heavy ion beams. In this work, a wall-less tissue equivalent proportional counter has been used for the measurement of lineal energy (y) distributions and dose-mean of y (yD) at radial direction of 30 MeV H at TIARA, for the verification of the microdosimetric function of PHITS. The measured yf(y) summed in radial direction agree with the corresponding data from the microdosimetric calculations using the PHITS code fairly well. The yD of 30 MeV proton beam presents the smallest value at r = 0.0 and gradually increase with radial distance, while the values of heavy ions such as iron showed rapid decrease with radial distance. This experimental result demonstrates that the stochastic deposit energy distribution of high-energy protons in microscopic region is rather constant both in the core and in the penumbra region of the track structure.

Journal Articles

Measurements and evaluations of air dose rates around Fukushima, 2; Meanings and features of dose quantities used in radiation protection

Saito, Kimiaki; Yamamoto, Hideaki

Radioisotopes, 63(11), p.519 - 530, 2014/11

This article aims to provide the basic meanings and features of the doses frequently used in the measurements and evaluations of environmental radiation due to the Fukushima Dai-ichi Nuclear Power Plant accident. The following doses are explained and compared: absorbed dose as basic physical quantity; effective dose and equivalent dose for judgment in radiation protection; and ambient dose equivalent $$H^{*}$$(10) and individual dose equivalent $$H$$p(10) for radiation measurements.

JAEA Reports

Radiation monitoring data of the HTTR rise-to-power test; Results up to 30MW operation on the high-temperature test operation mode

Ashikagaya, Yoshinobu; Kawasaki, Tomokatsu; Yoshino, Toshiaki; Ishida, Keiichi

JAERI-Tech 2005-010, 81 Pages, 2005/03

JAERI-Tech-2005-010.pdf:16.65MB

no abstracts in English

Journal Articles

Conceptual design of spectrum changeable neutron calibration fields in JAERI/FRS

Saegusa, Jun; Tanimura, Yoshihiko; Yoshizawa, Michio; Yoshida, Makoto

Radiation Protection Dosimetry, 110(1-4), p.91 - 95, 2004/09

 Times Cited Count:4 Percentile:23.52(Environmental Sciences)

For the accurate estimation of neutron dose equivalents, it is important to calibrate dosemeters in the field whose energy spectrum is similar to that in the workplace. For the purpose, studies are made toward the built of the spectrum changeable neutron calibration fields with the Van-de-Graff accelerator in the FRS in JAERI. The fields are produced by bombarding proton or deuteron beam from the accelerator to suitable targets surrounded by quasi-cylindrical moderators and absorbers of various materials. In the fields, neutron spectra with wide range energy index should be provided with sufficient fluence rate for the calibration of dosemeters. The objectives and conceptual design of the fields are discussed here, followed by the test simulation results of neutron spectra produced by various arrangements of a target and moderators.

Journal Articles

Neutron spectra and angular distributions of concrete-moderated neutron calibration fields at JAERI

Yoshizawa, Michio; Tanimura, Yoshihiko; Saegusa, Jun; Nemoto, Hisashi*; Yoshida, Makoto

Radiation Protection Dosimetry, 110(1-4), p.81 - 84, 2004/09

 Times Cited Count:3 Percentile:23.52(Environmental Sciences)

The facility of Radiation Standards (FRS) of JAERI has equipped with the concrete-moderated neutron calibration fields as simulated workplace neutron fields. The fields use an Am-Be (37GBq) neutron source placed in the narrow space surrounded by concrete wall and bricks to produce scattered neutrons. The neutron spectra of the fields were measured with Bonner multi-sphere spectrometer system (BMS), spherical recoil-proton proportional counters (RPCs), and a liquid scintillation counter (NE-213). The results were compared with each other, and the neutron spectra and the ambient dose equivalent rate, ${it H}$$$^{*}$$(10), were agreed well within the uncertainty. The angular distributions of neutron fluence were calculated by the MCNP-4B2 Monte Carlo code to obtain the reference personal dose equivalent rate, ${it H}$$$_{p}$$(10). The calculated results show that the scattered neutrons have a wide variety of incident angles. The reference ${it H}$$$_{p}$$(10) values considered the angular distribution were found to be 10-18% smaller than those without consideration.

Journal Articles

Dose evaluation in criticality accident conditions using transient critical facilities fueled with a fissile solution

Nakamura, Takemi*; Tonoike, Kotaro; Miyoshi, Yoshinori

Radiation Protection Dosimetry, 110(1-4), p.483 - 486, 2004/09

 Times Cited Count:2 Percentile:17.18(Environmental Sciences)

Dose measurement and evaluation technique in criticality accident conditions with a thermo luminescence dosimeter (TLD) was studied at the Transient Experiment Critical Facility (TRACY) of Japan Atomic Energy Research Institute (JAERI). The tissue absorbed dose can be derived from the ambient dose equivalent given by measurement with a TLD using the conversion factor given by computation. Using this technique, the neutron dose around the SILENE reactor of the Institute for Radioprotection and Nuclear Safety (IRSN) of France was measured in the Accident Dosimetry Intercomparison Exercise (June 10-21, 2002) organized by OECD/NEA and IRSN. In this exercise, the $$gamma$$ dose was also measured with a TLD. In this report, measurements and evaluation results at TRACY and SILENE are presented.

JAEA Reports

Results of shielding performance test in rise-to-power test of the HTTR

Ueta, Shohei; Takada, Eiji*; Sumita, Junya; Shimizu, Atsushi; Ashikagaya, Yoshinobu; Umeda, Masayuki; Sawa, Kazuhiro

JAERI-Tech 2004-047, 87 Pages, 2004/06

JAERI-Tech-2004-047.pdf:6.24MB

In the radiation shielding design of the High Temperature Engineering Test Reactor (HTTR), strong attention is needed to avoid especially upward neutron streaming. Shielding performance test have been carried out in the Rise-to-power test up to full power operation of 30MW. The measured dose equivalent rates in unrestricted area were lower than the detection limit for neutron-ray, and background level for $$gamma$$-ray. The neutron dose equivalent rate measured in the stand pipes room was about 120$$mu$$Sv/h at full power operation, which was much lower than the shielding design (330 mSv/h) and the prediction (10 mSv/h).

JAEA Reports

Radiation monitoring data of the HTTR rise-to-power test; Results up to 30 MW operation on the rated operation mode

Ashikagaya, Yoshinobu; Yoshino, Toshiaki; Yasu, Katsuji; Kurosawa, Yoshiaki; Sawa, Kazuhiro

JAERI-Tech 2002-094, 80 Pages, 2002/12

JAERI-Tech-2002-094.pdf:12.8MB

no abstracts in English

JAEA Reports

JAEA Reports

Dose equivalent rate and radiation monitoring results during power distribution measurements of HTTR

Takada, Eiji*; Fujimoto, Nozomu; Nojiri, Naoki; Umeta, Masayuki; Kokusen, Shigeru; Ashikagaya, Yoshinobu

JAERI-Data/Code 2002-009, 83 Pages, 2002/05

JAERI-Data-Code-2002-009.pdf:3.51MB

Dose equivalent rate around the fuel handling machine, the control rod handling machine, stand pipe compartment, maintenance pit were measured during gamma ray measurements from HTTR fuel, which was called as “power distribution measurements". The power distribution measurement was the first time to handle the fuel blocks irradiated in the core. Dose equivalent rate measurement aiming the check of shielding performance of components, the check of unexpected streaming path. The radiation monitoring during operation was carried out. As the results, there was no problem on shielding. The measured data at operation condition were also obtained. The data will be useful to expect operation circumstance in the future.

JAEA Reports

Characteristics of radiophotoluminescent glass dosimeters, FY2000

Ito, Masashi; Shiraishi, Akemi; Murakami, Hiroyuki

JAERI-Tech 2001-048, 20 Pages, 2001/07

JAERI-Tech-2001-048.pdf:1.27MB

In Japan Atomic Energy Research Institute, a new type radiophotoluminescent(RPL) glass dosimeter is recently adopted replaced film badge for external personal monitoring. Some fundamental characteristics of this dosimeter, such as dose dependence linearity, energy dependence, dose evaluation accuracy against mixed irradiation condition,fading, etc.,were examined at the Facility of Radiation Standard(FRS),JAERI. The results have proved that the RPL glass dosimeter has sufficient characteristics in practical use as a personal dosimeter for all of the items examined.

60 (Records 1-20 displayed on this page)